EHCI: only power off port if over-current is active
BugLink: http://bugs.launchpad.net/bugs/823296 commit 81463c1d707186adbbe534016cd1249edeab0dac upstream. MAX4967 USB power supply chip we use on our boards signals over-current when power is not enabled; once it's enabled, over-current signal returns to normal. That unfortunately caused the endless stream of "over-current change on port" messages. The EHCI root hub code reacts on every over-current signal change with powering off the port -- such change event is generated the moment the port power is enabled, so once enabled the power is immediately cut off. I think we should only cut off power when we're seeing the active over-current signal, so I'm adding such check to that code. I also think that the fact that we've cut off the port power should be reflected in the result of GetPortStatus request immediately, hence I'm adding a PORTSCn register readback after write... Signed-off-by: Sergei Shtylyov <sshtylyov@ru.mvista.com> Acked-by: Alan Stern <stern@rowland.harvard.edu> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de> Signed-off-by: Stefan Bader <stefan.bader@canonical.com> Signed-off-by: Tim Gardner <tim.gardner@canonical.com>
parent
10233290
Please register or sign in to comment