Skip to content
Commit 166d3c79 authored by Frederic Weisbecker's avatar Frederic Weisbecker Committed by Ingo Molnar
Browse files

tracing/function-graph-tracer: improve duration output



Impact: better trace output of duration for long calls

The old duration output didn't exceeded 9999.999 us to fit the column
and the nanosecs were always 3 numbers. As Ingo suggested, it's better
to have the whole microseconds elapsed time and shift the nanosecs precision
if needed to fit the maximum 7 numbers. And usec need more number, the case
should be rare and important enough to break a bit the column alignment to
show it.

So, depending of the duration value, we now have these patterns:

    u.nnn us
   uu.nnn us
  uuu.nnn us
 uuuu.nnn us
 uuuuu.nn us
 uuuuuu.n us
 uuuuuuuu..... us

Signed-off-by: default avatarFrederic Weisbecker <fweisbec@gmail.com>
Signed-off-by: default avatarIngo Molnar <mingo@elte.hu>
parent 11e84acc
0% or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment