powerpc/spufs: fix missed stop-and-signal event
There is a delay in the transition to the stopped state for class 2 interrupts. In some cases, the controlling thread detects the state of the spu as running, and goes back to sleep resulting in a hung application as the event is missed. This change detects the stop condition and re-generates the wakeup event after a context save. Signed-off-by: Luke Browning <lukebrowning@us.ibm.com> Signed-off-by: Jeremy Kerr <jk@ozlabs.org>
parent
2c911a14